H panel is used in interior partition walls ,containers and prefabricated Buildings. It is produced as 1250mm width and as Mesa pattern.

| Insulation Material |
Fire Class |
Density |
Insulation Thickness (mm) |
Thermal Conductivity (λ) |
U Value | R Value |
|---|---|---|---|---|---|---|
| (W/m2K) | (h·ft²·°F/Btu) | |||||
| Polyisocyanurate (PIR) |
B s1 d0 (TS EN 13501-1) |
42 (±2)kg/m3 | 40 | 0.020 W/mK | 0,53 | 11 |
| 50 | 0,43 | 13 | ||||
| 60 | 0,34 | 17 | ||||
| 80 | 0,25 | 23 | ||||
| 100 | 0,20 | 28 | ||||
| 120 | 0,17 | 34 | ||||
| 150 | 0,13 | 43 | ||||
| 180 | 0,11 | 51 | ||||
| 200 | 0,10 | 57 | ||||
| External Sheet | Prepainted Galvanized Steel/Aluminium 0.35-0.40-0,45-0,50-0,60-0,70 mm | |||||
| Internal Sheet | Prepainted Galvanized Steel/Aluminium 0.30-0.35-0.40-0,45-0,50-0,60-0,70 mm | |||||
U value calculated due to TS EN 14509.U value converted to American R Value.
| Insulation Material |
Insulation Thickness (mm) |
External Steel (mm) |
Internal Steel (mm) |
Weight (kg/m2) |
Span Type (mm) |
Span Distance | ||||
|---|---|---|---|---|---|---|---|---|---|---|
| 1000 | 1500 | 2000 | 2500 | 3000 | ||||||
| M ax.Distributed Load (kg/m2) | ||||||||||
| Polyisocyanurate (PIR) |
40 | 0,50 | 0,40 | 10,72 | Two Span | 234 | 180 | 137 | 103 | x |
| Multi Span | 241 | 185 | 147 | 117 | x | |||||
| 50 | 0,50 | 0,40 | 11,14 | Two Span | 309 | 242 | 201 | 151 | x | |
| Multi Span | 316 | 249 | 203 | 168 | 107 | |||||
| 60 | 0,50 | 0,40 | 11,56 | Two Span | 384 | 305 | 257 | 212 | 136 | |
| Multi Span | 392 | 313 | 262 | 220 | 140 | |||||
| 80 | 0,50 | 0,40 | 12,40 | Two Span | 537 | 435 | 373 | 324 | 206 | |
| Multi Span | 545 | 445 | 381 | 330 | 215 | |||||
| 100 | 0,50 | 0,40 | 13,24 | Two Span | 692 | 567 | 492 | 436 | 297 | |
| Multi Span | 699 | 579 | 503 | 444 | 304 | |||||
| 120 | 0,50 | 0,40 | 14,08 | Two Span | 848 | 702 | 613 | 549 | 397 | |
| Multi Span | 854 | 713 | 626 | 559 | 408 | |||||
| 150 | 0,50 | 0,40 | 15,34 | Two Span | 1083 | 906 | 799 | 721 | 566 | |
| Multi Span | 1089 | 918 | 813 | 736 | 574 | |||||
| 180 | 0,50 | 0,40 | 16,60 | Two Span | 1318 | 1112 | 988 | 897 | 708 | |
| Multi Span | 1324 | 1123 | 1003 | 914 | 720 | |||||
| 200 | 0,50 | 0,40 | 17,44 | Two Span | 1476 | 1476 | 1114 | 1016 | 804 | |
| Multi Span | 1481 | 1261 | 1131 | 1034 | 818 | |||||
Notes:
. Values have been calculated using the allowable “Stress Design” method, taking self weight, imposed loads (wind load) and temperature (Δt=±20ºC) into account.
. If loads are effected as downwards l/200 and l/150 , ıf loads are effected as suction l/150 deflection limits have been used
. In Panel weight calculations, Polyurethane density is taken as 40 kg/m3 and Polyisocyanurate density is taken as 42 kg/m3.
. Values have been calculated using the steel quality fγ=240 Mpa(Yield Strength).