- General Information
- Technicial Specifications
- Surface Shapes
The Cold Rooms which are built to store the products in a healthy way at temperatures up to -40°C, cause high energy consumption to stay in low temperatures.PUR/PIR insulated cold room panel is the ideal building material to obtain heat insulation in cold room aplications to lower down the energy costs.
Determining the thickness of Cold Room panels depend on many factors;
- The difference of the temperature between inside and outside of the structure
- The type of the insulation core of Sandwich Panel
- Energy costs
- Building cost
- Design of Cooling System


| Insulation Material |
Fire Class |
Density |
Insulation Thickness (mm) |
Thermal Conductivity (λ) |
U Value | R Value |
|---|---|---|---|---|---|---|
| (W/m2K) | (h·ft²·°F/Btu) | |||||
| Polyurethane (PUR) |
B s2 d0 (TS EN 13501-1) |
40 (±2)kg/m3 | 80 | 0,022 W/mK | 0,27 | 21 |
| 100 | 0,22 | 26 | ||||
| 120 | 0,18 | 31 | ||||
| 150 | 0,15 | 39 | ||||
| 180 | 0,12 | 47 | ||||
| 200 | 0,11 | 52 | ||||
| External Sheet | Prepainted Galvanized Steel/Stainless Steel 0,50-0,60-0,70 mm | |||||
| Internal Sheet | Prepainted Galvanized Steel/Stainless Steel 0,50-0,60-0,70 mm | |||||
Technical documents
The library contains general documents and historical references. Ask the technical team for a current file matching this system, thickness and project requirements.
Confirm this system for your project.
Send the application, location, area, thickness and performance requirements. The system code is included automatically.