- General Information
- Technical Specifications
- Payload Table
Slope is less than 5%; It is used on the roofs and walls of large-sized buildings with steel or prefabricated carrier systems, such as factory buildings, industrial buildings, sports facilities, hypermarkets, shopping malls, market buildings.
| Isolation Material |
Flammability Class |
Isolation Density |
Isolation Thickness (mm) |
Thermal Conductivity Coefficient (λ) |
U Value | R Value |
|---|---|---|---|---|---|---|
| (W/m2K) | (h·ft²·°F/Btu) | |||||
| Rockwool | A2 s1 d0 (TS EN 13501-1) |
90-100-110-120 kg/m3 | 50 | 0.036 W/mK | 0.68 | 8 |
| 60 | 0.58 | 10 | ||||
| 80 | 0.44 | 13 | ||||
| 100 | 0.35 | 16 | ||||
| 120 | 0.29 | 19 | ||||
| 150 | 0.24 | 24 | ||||
| Skin | 1.20~1.50mm thick TPO or PVC Membrane | |||||
| Inside | Painted Galvanized Sheet 0.50-0.60-0.70 mm | |||||
U value is calculated in accordance with TS EN 14509. The U value has been converted to the American R value.
| Product Name |
Metal Thickness (mm) |
Panel Weight (kg/m2) |
Span (mm) |
Pearl Range | ||||
|---|---|---|---|---|---|---|---|---|
| 1000 | 1500 | 2000 | 2500 | 3000 | ||||
| Max.Spread Load (kg/m2) | ||||||||
| 32/250 Trapeze |
0.40 | 3.77 | Two Span | 341 | 208 | 108 | 58 | 51 |
| Three Span | 393 | 242 | 128 | 70 | 63 | |||
| 0.50 | 4.71 | Two Span | 421 | 258 | 135 | 72 | 63 | |
| Three Span | 485 | 297 | 162 | 90 | 77 | |||
| 0.60 | 5.65 | Two Span | 489 | 312 | 163 | 87 | 76 | |
| Three Span | 558 | 356 | 194 | 106 | 94 | |||
| 0.70 | 6.59 | Two Span | 562 | 364 | 190 | 101 | 91 | |
| Three Span | 641 | 415 | 230 | 124 | 112 | |||
Notes:
. “Safety Stress” method was used in the calculations. Self-weight, live load (wind load) and temperature change (Δt=±20ºC) are taken into account.
. The deflection limit is taken as L/200 and L/150 if the loads act as pressure, and L/150 if the loads act as suction.
. Sheet quality is based on fγ=240 Mpa (Yield Strength).