Skip to main content
Metapanel
AR
Archived technical reference

MP-R5M 5 Ribbed-Membrane Roof Panel

System code
MP-R5M
Application
Roof panels
Insulation / group
Rock wool insulated
Data status
Recovered from archive
Source pages
2
Technical illustration    
  • General Information
  • Technical Specifications
  • Payload Table

Slope is less than 5%; It is used on the roofs and walls of large-sized buildings with steel or prefabricated carrier systems, such as factory buildings, industrial buildings, sports facilities, hypermarkets, shopping malls, market buildings.

Technical illustration
Isolation
Material
Flammability
Class
Isolation
Density
Isolation
Thickness (mm)
Thermal Conductivity
Coefficient (λ)
U Value R Value
(W/m2K) (h·ft²·°F/Btu)
Rockwool A2 s1 d0
(TS EN 13501-1)
90-100-110-120 kg/m3 50 0.036 W/mK 0.68 8
60 0.58 10
80 0.44 13
100 0.35 16
120 0.29 19
150 0.24 24
Skin 1.20~1.50mm thick TPO or PVC Membrane
Inside Painted Galvanized Sheet 0.50-0.60-0.70 mm

U value is calculated in accordance with TS EN 14509. The U value has been converted to the American R value.

Product Name
 
Metal Thickness
(mm)
Panel Weight
(kg/m2)
Span
(mm)
Pearl Range
1000 1500 2000 2500 3000
Max.Spread Load (kg/m2)
32/250
Trapeze
0.40 3.77 Two Span 341 208 108 58 51
Three Span 393 242 128 70 63
0.50 4.71 Two Span 421 258 135 72 63
Three Span 485 297 162 90 77
0.60 5.65 Two Span 489 312 163 87 76
Three Span 558 356 194 106 94
0.70 6.59 Two Span 562 364 190 101 91
Three Span 641 415 230 124 112

Notes:
. “Safety Stress” method was used in the calculations. Self-weight, live load (wind load) and temperature change (Δt=±20ºC) are taken into account.
. The deflection limit is taken as L/200 and L/150 if the loads act as pressure, and L/150 if the loads act as suction.
. Sheet quality is based on fγ=240 Mpa (Yield Strength).

Technical documents

The library contains general documents and historical references. Ask the technical team for a current file matching this system, thickness and project requirements.

Confirm this system for your project.

Send the application, location, area, thickness and performance requirements. The system code is included automatically.

Request technical review