Skip to main content
Metapanel
AR
Materials & insulation

Galvanized Sheet

Painted galvanized is a 100-275 gr/m² zinc coated sheet, galvanized in continuous lines by hot dipping method, in accordance with EN 10143:2006 standard. Galvanized coating increases the corrosion resistance of the sheet. Galvanized sheet metal is resistant to impacts and wear due to its hardness. Galvanized sheet thickness on the carrier surface is min. It should be used with a thickness of 0.50mm.

Sheet
Quality
Thickness
Tolerance
Pull
Strength
%
on break Extension
Coating Amount (Zinc) Dye Type
DX51D+Z ±0.05MM 270-500 Min 22* 100-275 gr/m² Polyester,
PVdf,
Plastisol,Silic
on
Polyester,Poly
urethane
EN 10143:2006 EN 10143:2006 EN 10143:2006 EN 10143:2006 EN 10143:2006
*Min for thicknesses less than or equal to 0.70mm. The elongation value should be evaluated 2 units less.
EN
10143:2006
DX51D Thickness Tolerances
Nominal Thickness (mm) Roll Width
≤1200mm 1200<t≤1500mm >1500mm
0.20<t≤0.40 ±0.05 ±0.06 ±0.07
0.40<t≤0.60 ±0.05 ±0.06 ±0.07
0.60<t≤0.80 ±0.06 ±0.07 ±0.08
0.80<t≤1.00 ±0.07 ±0.08 ±0.09
1.00<t≤1.20 ±0.08 ±0.09 ±0.11